Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: https://er.knutd.edu.ua/handle/123456789/30956
Повний запис метаданих
Поле DCЗначенняМова
dc.contributor.advisorVoloshyna, Iryna-
dc.contributor.authorZhu, Junjie-
dc.date.accessioned2025-09-11T08:36:32Z-
dc.date.available2025-09-11T08:36:32Z-
dc.date.issued2025-06-
dc.identifier.citationZhu Junjie. Establishment of PCR detection methods for drug-resistance gene mcr-8 : master's thesis оf the specialty first (Bachelor's) level of higher education Specialty 162 "Biotechnology and Bioengineering" Educational and professional program "Biotechnology" / Zhu Junjie ; scientific supervisor Iryna Voloshyna ; reviewer Olga Iungin. – Kyiv : KNUTD, 2025. – 44 p.uk
dc.identifier.urihttps://er.knutd.edu.ua/handle/123456789/30956-
dc.description.abstractThe emergence of bacterial resistance seriously threatens the sustainable development of public health and animal husbandry. Polymyxin is a key drug for clinical treatment of gram-negative bacteria infection and the last line of defense to prevent and control bacterial infection. The mobile colistin resistance-8 (mcr-8) gene is one of the main genes that cause bacteria to develop polymyxin resistance. This study designed and established a specific PCR detection method for the mcr-8 gene to be used to quickly screen and monitor the mcr-8 gene. According to the mcr-8 gene sequence, a pair of specific primers were designed using the primer design software Oligo 7 to amplify the conserved region of the target gene mcr-8.1 (101-1798), and the theoretical amplification product length was 1268 bp. The physical and chemical properties of the designed primers meet the requirements, their GC content is moderate (47.6% and 52.6%), and the Tm value is stable at 59.4℃. Specific verification showed that samples containing only the mcr-8 gene showed 1268 bp specific amplification products, and no target bands were observed in the negative control group; the positive control PCR product was sequenced, and the BLAST comparison showed that the sequence consistency with the mcr-8 gene was 100%, which confirmed that the method was highly specific. Sensitivity analysis shows that the lower limit of detection of mcr-8 plasmid DNA in this system can reach 10 pg. Through detection of 15 clinical isolates (including 10 E. coli and 5 Salmonella strains), the mcr-8 gene was not detected in all the tested strains. The PCR detection method of mcr-8 gene established in this study provides effective technical means for the rapid detection of bacterial resistance, and has important application value in the fields of clinical treatment and bacterial resistance monitoring.uk
dc.language.isoenuk
dc.publisherКиївський національний університет технологій та дизайнуuk
dc.subjectmcr geneuk
dc.subjectSalmonellauk
dc.subjectcolistin resistanceuk
dc.subjectagarose gel electrophoresisuk
dc.subjectPCRuk
dc.subjectmcr-8 geneuk
dc.titleEstablishment of PCR detection methods for drug-resistance gene mcr-8uk
dc.typeДипломний проектuk
local.subject.facultyФакультет хімічних та біофармацевтичних технологійuk
local.subject.departmentКафедра біотехнології, шкіри та хутраuk
local.subject.method1uk
local.diplom.groupBEBT-21uk
local.diplom.okrБакалаврuk
local.diplom.speciality162 Biotechnology and Bioengineeringuk
local.diplom.programBiotechnologyuk
Розташовується у зібраннях:Бакалаврський рівень

Файли цього матеріалу:
Файл Опис РозмірФормат 
Diplom162_Junjie Zhu_Voloshyna.pdf698,92 kBAdobe PDFПереглянути/Відкрити


Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.